Informix - Problembeschreibung
Problem IT18155 | Status: Geschlossen |
"PTHDRPAGE:PTALLOC:BAD PARTN PAGE" ASSERTIONS POSSIBLE RUNNING PURGE_DICTIONARY TASK | |
Produkt: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problembeschreibung: | |
Should compression dictionary partitions contain old dictionaries for partnums whose partition header pages now serve as secondary partition header pages (describing in-place alters), purging such dictionaries using sysadmin:task("compression purge_dictionary") would throw an assertion like the following for every such dict_partnum in sysmaster:syscompdicts: Assert Warning: pthdrpage:ptalloc:bad partn page IBM Informix Dynamic Server Version 12.10.FC7 Who: Session(1186, user@host, 12519, 0x44909858) Thread(1325, sqlexec, 448d2dd8, 1) File: rspartn.c Line: 8576 Results: Cannot use TBLSpace page for TBLSpace 1049198 Action: Run 'oncheck -pt 1049198' stack trace for pid 31122 written to /informix/dump/dir/af.9159ef9 These really are warnings only and would neither pose nor create any problem. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * Using compression and purging compression dictionary after * * some tables were dropped and others were altered. * **************************************************************** * PROBLEM DESCRIPTION: * * Unnecessary assertion failure warning messages in the * * message log file. Also see the Error Description. * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC9 or newer. * **************************************************************** | |
Local-Fix: | |
Lösung | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 29.11.2016 10.07.2017 10.07.2017 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
12.10.xC9 | |