Informix - Problembeschreibung
Problem IT18613 | Status: Geschlossen |
NETWORK COMMUNICATION FAILURE DURING SDS CONNECTION TO PRIMARY MAY LEAD TO CHECKPOINT HANG | |
Produkt: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problembeschreibung: | |
When an SDS server is starting it will connect to the primary and request a blocking checkpoint in order to ensure all modified pages have been flushed to disk prior to the SDS server accessing them. If there is a problem with network communications during this activity, or the SDS server goes down for some reason, then the primary server may hang in a later checkpoint request. Additionally if the SDS server is restarted then it will fail to connect to the primary. A shutdown and restart of the primary is required to resolve the problem. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * Users of a cluster with secondary servers * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC9 * **************************************************************** | |
Local-Fix: | |
Lösung | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 29.12.2016 10.07.2017 10.07.2017 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
12.10.xC9 | |
Problem behoben lt. FixList in der Version |