Informix - Problembeschreibung
Problem IT19140 | Status: Geschlossen |
A PROXYTH THREAD CAN BE LEFT ORPHANED HOLDING LOCKS ON THE PRIMARY SERVER WHEN A PROXY DISPATCH THREAD FAILS | |
Produkt: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problembeschreibung: | |
A proxyTh thread can be left on the primary holding locks even when the corresponding session in the secondary server is already terminated. The proxyTh thread can be holding locks which are not released until the secondary is restarted or the proxyTh session hits a long transaction. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * All users * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC9 * **************************************************************** | |
Local-Fix: | |
Restart secondary or let session hit a long transaction. | |
Lösung | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 06.02.2017 10.07.2017 10.07.2017 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
12.10.xC9 | |
Problem behoben lt. FixList in der Version |