Problem IT21280 Status: Geschlossen

WITH DELAY_APPLY SET WHEN PRIMARY IS RESTARTED AFTER THE LOGICALLOG WRAP
IT STOPS SENDING NEW LOGICAL LOGS TO RSS UNTIL DELAY_A

Produkt:
INFORMIX SERVER / 5725A3900 / B70 - IDS 11.70
Problembeschreibung:
When DELAY_APPLY is set on RSS and primary is restarted after
the logical log wrap, RSS doesn't reconnect to Primary and new
logical logs are not sent to the staging directory until
DELAY_APPLY is elapsed and logical logs from staging directory
are applied at RSS.  Following message is seen in the RSS
online.log

14:45:31  SMX thread is exiting
14:45:34  RSS: Lost connection to pri_root
14:45:52  RSS: Reconnected to pri_root
14:45:52  RSS: Start failure recovery from tape ...

This behavior is NOT seen on 12.10.FC8.
Problem-Zusammenfassung:
Local-Fix:
Lösung
Workaround
keiner bekannt / siehe Local-Fix
Kommentar
This APAR is a duplicate of IT27580
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
03.07.2017
25.09.2019
26.10.2019
Problem behoben ab folgender Versionen (IBM BugInfos)
Problem behoben lt. FixList in der Version
Informix EditionenInformix Editionen
Informix Editionen
DokumentationDokumentation
Dokumentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download