Informix - Problembeschreibung
Problem IT22800 | Status: Geschlossen |
A GLITCH IN TENANT POINT-IN-TIME CODE CAUSES SWITCH() STATEMENT IN APPLY_LOGREC() TO FALL THROUGH INCORRECTLY | |
Produkt: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problembeschreibung: | |
A change made to apply_logrec() in 2015 caused the LG_ADDCHK and LG_DRPCHK cases in a switch statement to fall through when they should have returned a value of 1. Fortunately the main code in the next case was then skipped, and we happened to return a value of 1 at the end of that case. This existing problem was exposed by the insertion of a different case to the switch statement() below the problem point. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * All platforms * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC10 * **************************************************************** | |
Local-Fix: | |
Lösung | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 16.10.2017 01.11.2017 01.11.2017 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
12.10.xC10 | |
Problem behoben lt. FixList in der Version |