Informix - Problembeschreibung
Problem IT27262 | Status: Geschlossen |
ONMODE -- OUTPUT SHOWS THE WRONG USAGE SYNTAX FOR ONMODE -I | |
Produkt: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problembeschreibung: | |
If you run onmode -- to get the usage, it includes the following line: -I [] trap specified error for session ID This is INCORRECT USAGE! It needs to be: -I [,] trap specified error for session ID The comma is very important. Without it, the two specified numbers will be treated as two errors to trap FOR ALL SESSIONS instead of the first being the error to trap and the second being a particular session ID. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * Users of IDS prior to 12.10.xC13. * **************************************************************** * PROBLEM DESCRIPTION: * * onmode -- output shows the wrong usage syntax for onmode -I * **************************************************************** * RECOMMENDATION: * **************************************************************** | |
Local-Fix: | |
Lösung | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 10.12.2018 26.09.2019 31.08.2020 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
12.10.xC13 | |
Problem behoben lt. FixList in der Version |