suche 36x36
  • Admin-Scout-small-Banner
           

    CURSOR Admin-Scout

    das ultimative Tool für Informix

    pfeil  
Neueste VersionenFixList
14.10.xC10 FixList
12.10.xC16.X5 FixList
11.70.xC9.XB FixList
11.50.xC9.X2 FixList
11.10.xC3.W5 FixList
Haben Sie Probleme? - Kontaktieren Sie uns.
Kostenlos registrieren anmeldung-x26
Kontaktformular kontakt-x26

Informix - Problembeschreibung

Problem IT27466 Status: Geschlossen

WINDOWS 12.10.TC9 RUNNING ONSMSYNC AS ADMINISTRATOR FAILS TO BUILD IXBAR
FILE WITH PERMISSION DENIED

Produkt:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problembeschreibung:
When you run any onsmsync command as Administrator in Windows
the ixbar file will fail to be accessed with Permission denied.
You will see the same behavior with 'onsmsync -b' but here is
bar_act/debug output from running onsmsync -g 1:

bar_act.log:
 2017-11-15 18:05:01 3876[3544]  3876 onsmsync -g 1
 2017-11-15 18:05:01 3876[3544]  3876 Using IBM Corporation's
TSM version 5.3.2.0 as the Storage Manager. XBSA API version is
1.0.3.
 2017-11-15 18:05:01 3876[3544]  3876 Successfully connected to
Storage Manager.
 2017-11-15 18:05:03 3876[3544]  3876 Syncing sysutils and
bootfile...
 2017-11-15 18:05:04 3876[3544]  3876 Successfully connected to
Storage Manager.
 2017-11-15 18:05:04 3876[3544]  3876 Querying for backups
expired at Storage Manager...
 2017-11-15 18:05:05 3876[3544]  3876 Building current
timeline...
 2017-11-15 18:05:05 3876[3544]  3876 Applying expiration
policies...
 2017-11-15 18:05:06 3876[3544]  3876 Regenerating sysutils and
bootfile...
 2017-11-15 18:05:06 3876[3544]  3876 (-43050) Copy of old
emergency bootfile saved in
D:InformixIDSetcixbar.0.20171115.180506 .
 2017-11-15 18:05:06 3876[3544]  3876 (-43049) Error writing to
the ON-Bar emergency boot file. Before attempting a
restore, insert the following into the ON-Bar emergency boot
file: sew00vvm003        bapdbs0            ND 0 228   0 0
71683      2017-11-15 18:03:43 1     4659  754453609   228   0
- - 4659  1510787023  1510761754  98
Permission denied
 2017-11-15 18:05:06 3876[3544]  3876 onsmsync complete,
returning 127 (0x7f)


bar_debug.log:
2017-11-15 18:05:06 3876[3544]  3876 boot_write: return 127
(0x7f)
2017-11-15 18:05:06 3876[3544]  3876 bar_regen_bootfile: close
s_regen_crs
2017-11-15 18:05:06 3876[3544]  3876 bar_regen_bootfile: free
s_regen_stmt
2017-11-15 18:05:06 3876[3544]  3876 boot_close: enter
2017-11-15 18:05:06 3876[3544]  3876 boot_close: input
*boot_handle 0x00000005
2017-11-15 18:05:06 3876[3544]  3876 boot_close: output
*boot_handle 0xffffffff
2017-11-15 18:05:06 3876[3544]  3876 boot_close: return 0 (0x00)
2017-11-15 18:05:06 3876[3544]  3876 bar_regen_bootfile: return
127 (0x7f)
2017-11-15 18:05:06 3876[3544]  3876 bar_smsync_exec: return 127
(0x7f)
2017-11-15 18:05:06 3876[3544]  3876 barTerminate: enter
2017-11-15 18:05:06 3876[3544]  3876 bar_loadXBSA: return 0
2017-11-15 18:05:06 3876[3544]  3876 barTerminate: return 0
(0x00)
2017-11-15 18:05:06 3876[3544]  3876 onsmsync main: return 127
(0x7f)
2017-11-15 18:05:06 3876[3544]  3876 bar_cleanup: enter
2017-11-15 18:05:06 3876[3544]  3876 bar_srv_status: enter
2017-11-15 18:05:06 3876[3544]  3876 bar_srv_status: return 5
(0x05)


The only way to get a new ixbar file is to run an L0 backup.
Problem-Zusammenfassung:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC11.                *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* WINDOWS 12.10.TC9 RUNNING ONSMSYNC AS ADMINISTRATOR FAILS TO *
* BUILD IXBAR FILE WITH PERMISSION DENIED                      *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC11+.                      *
****************************************************************
Local-Fix:
Lösung
Workaround
keiner bekannt / siehe Local-Fix
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
21.12.2018
04.12.2019
04.12.2019
Problem behoben ab folgender Versionen (IBM BugInfos)
12.10.xC11
Problem behoben lt. FixList in der Version
Informix EditionenInformix Editionen
Informix Editionen
DokumentationDokumentation
Dokumentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download