Informix - Problembeschreibung

Problem IT27508 Status: Geschlossen

DBSCHEMA AND "SELECT * FROM SYSINDEXES" FAIL WITH -201 ERROR AFTER
MIGRATION AND REVERSION 11.50->12.10->11.50

Produkt:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problembeschreibung:
If you initialize an instance of 11.50.FC9W3 (for example),
create the stores_demo database, then migrate that in-place to
12.10.FC10 and then revert back to 11.50.FC9W3, dbschema of the
entire stores_demo database or any single table will fail with
-201.

Setting a trap for -201 shows that dbschema is failing while
trying to run this SQL:

  select c.coltype, c.collength  from informix.syscolumns c,
    informix.sysindexes i  where i.tabid = c.tabid and i.tabid =
100 and
    (c.colno = ABS(i.part1) or c.colno = ABS(i.part2) or c.colno
=
    ABS(i.part3) or c.colno = ABS(i.part4) or c.colno =
ABS(i.part5) or
    c.colno = ABS(i.part6) or c.colno = ABS(i.part7) or c.colno
= ABS(i.part8)
    or c.colno = ABS(i.part9) or c.colno = ABS(i.part10) or
c.colno =
    ABS(i.part11) or c.colno = ABS(i.part12) or c.colno =
ABS(i.part13) or
    c.colno = ABS(i.part14) or c.colno = ABS(i.part15) or
c.colno =
    ABS(i.part16));

A simple "select * from sysindexes" also returns -201.

I noticed that the last record in sysviews for sysindexes is
this:

...

tabid     71
seqno     14
viewtext  ".sysindices x0 ;

tabid     71
seqno     15
viewtext

Looking at those two final rows, I see this:

slot  18:
    0:  0  0  0 47  0  e 22 2e 73 79 73 69 6e 64 69 63
...G..".sysindic
   16: 65 73 20 78 30 20 3b 20 20 20 20 20 20 20 20 20   es x0 ;

   32: 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20

   48: 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20

   64: 20 20 20 20 20 20
..........
slot  19:
    0:  0  0  0 47  0  f  0  0  0  0  0  0  0  0  0  0
...G............
   16:  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0
................
   32:  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0
................
   48:  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0  0
................
   64:  0  0  0  0  0  0
................

If I remove that last row (seqno=15), the -201 error goes away.

The problem does not reproduce for the sysmaster and sysutils
databases likely because they are rebuilt on 11.50 after
reversion.  But the problem does reproduce with the sysuser
database which is not rebuilt after reversion.
Problem-Zusammenfassung:
****************************************************************
* USERS AFFECTED:                                              *
* Users of IDS 12.10.xC10 and older versions.                  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* Dbschema and "select * from sysindexes" fail with -201 error *
* after migration and reversion 11.50->12.10->11.50.           *
****************************************************************
* RECOMMENDATION:                                              *
****************************************************************
Local-Fix:
Lösung
Workaround
keiner bekannt / siehe Local-Fix
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
24.12.2018
07.10.2019
07.10.2019
Problem behoben ab folgender Versionen (IBM BugInfos)
12.10.xC11
Problem behoben lt. FixList in der Version
Informix EditionenInformix Editionen
Informix Editionen
DokumentationDokumentation
Dokumentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download