Informix - Problembeschreibung
Problem IT27535 | Status: Geschlossen |
CDR SYNC/CHECK FAILING WITH -217 OR -392 IF DELIMIDENT TURNED ON | |
Produkt: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problembeschreibung: | |
There are numerous $select ... statements, issued by 'cdr sync' or 'cdr check' code, that would include clauses like 'where some_column = "string_value"' which typically would cause a failure including -217 or -392. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * Users of IDS 12.10.xC11 and older versions. * **************************************************************** * PROBLEM DESCRIPTION: * * Cdr sync/check failing with -217 or -392 if DELIMIDENT * * turned on. * **************************************************************** * RECOMMENDATION: * **************************************************************** | |
Local-Fix: | |
Lösung | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 26.12.2018 04.10.2019 04.10.2019 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
12.10.xC12 | |
Problem behoben lt. FixList in der Version |