Informix - Problembeschreibung

Problem IT28628 Status: Geschlossen

FAILED CONNECTIONS COULD LEAD TO INCORRECT VALUE FOR SHMEM->SH_RSNACTIVE
WHICH COULD CAUSE PHYSICAL LOG OVERFLOW ASSERTIONS

Produkt:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problembeschreibung:
Under specific failed connections, it's possible that
shmem->sh_rsnactive will be decremented prior to it having been
incremented.  If this happens often enough
shmem->sh_rsnactive can go to a negative value.  This can lead
to physical log overflow because this value is used in the code
to determine if a non-blocking checkpoint needs to be switched
to a blocking checkpoint, to prevent the physical log from
filling.

The most likely cause of failed connections would be servers
that have SHMTOTAL set to a non-zero value, and the server has
allocated SHMTOTAL amount of memory.

Fixed in 12.10.UC11
Problem-Zusammenfassung:
****************************************************************
* USERS AFFECTED:                                              *
* All operating systems.                                       *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* Under specific failed connections, it's possible that        *
* shmem->sh_rsnactive will be decremented prior to it having   *
* been                                                         *
* incremented.  If this happens often enough                   *
* shmem->sh_rsnactive can go to a negative value.  This can    *
* lead                                                         *
* to physical log overflow because this value is used in the   *
* code                                                         *
* to determine if a non-blocking checkpoint needs to be        *
* switched                                                     *
* to a blocking checkpoint, to prevent the physical log from   *
* filling.                                                     *
*                                                              *
* The most likely cause of failed connections would be servers *
* that have SHMTOTAL set to a non-zero value, and the server   *
* has                                                          *
* allocated SHMTOTAL amount of memory.                         *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to version 12.10.XC11                                *
****************************************************************
Local-Fix:
Lösung
Workaround
keiner bekannt / siehe Local-Fix
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
01.04.2019
08.10.2019
08.10.2019
Problem behoben ab folgender Versionen (IBM BugInfos)
12.10.xC11
Problem behoben lt. FixList in der Version
Informix EditionenInformix Editionen
Informix Editionen
DokumentationDokumentation
Dokumentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download