DB2 - Problembeschreibung
Problem IT25628 | Status: Geschlossen |
WIN32 ONLY: DB2LEVEL GIVES SQL1022C IF INSTANCE NAME IS LONGER THAN 7 BYTES. | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / B10 - DB2 | |
Problembeschreibung: | |
Win32 only: db2level gives SQL1022C if instance name is longer than 7 bytes. This steps illustrates how this problem happens. 1. Install Data Server Client 32-bit. 2. Create an instance named 8 bytes. C:>db2icrt DB123456 3. Switch to the instance C:>set DB2INSTANCE=DB123456 4. Run db2level. C:>db2level SQL1022C There is not enough memory available to process the command. CLP does not return errors, but some Db2 commands may fail. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * ALL * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Db2 11.1 Mod 4 Fixpack 5 or higher * **************************************************************** | |
Local-Fix: | |
Use instance name shorter than 8 bytes. | |
Lösung | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 10.07.2018 16.01.2020 16.01.2020 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
Problem behoben lt. FixList in der Version |