Informix - Problem description

Problem IT34066 Status: Closed

SET EXPLAIN OFF CAN CAUSE ASSERT FAIL CALLING MT_AIO_FCLOSE
FROMSETEXPLAIN

product:
INFORMIX SERVER / 5725A3900 / E10 - 
Problem description:
Shortly after bringing the server on-line, it's possible for the
server to assert with a stack like below when
running set explain off.

0x00000000014e501d (oninit) afstack
0x00000000014eabe1 (oninit) mt_ex_throw_sig
0x00000000014f8d68 (oninit) afsig_handler
0x00007fa64fe205e0 (Linux) 
0x00000000014cc299 (oninit) mt_aio_fclose
0x0000000000646a84 (oninit) setexplain
0x00000000007502de (oninit) aud_setexplain
0x0000000000640bd7 (oninit) excommand
0x0000000000af260b (oninit) sq_execute_workhorse
0x0000000000af2e4d (oninit) sq_execute
0x0000000000bc655e (oninit) sqmain
0x0000000001613a7a (oninit) spawn_thread
0x00000000014d5cf2 (oninit) th_init_initgls
0x000000000151c00f (oninit) startup

The problem has a generally reliable reproduction, but after it
asserts for the first time on a cpu vp
it seems to no longer reproduce.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 14.10.xC5.                 *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Update to Informix Server 14.10.xC5.                         *
****************************************************************
Local Fix:
Setting the following onconfig parameter may work around the
problem:

STMT_CACHE_QUERY_PLAN 0
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 14.10.xC5.                 *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Update to Informix Server 14.10.xC5.                         *
****************************************************************
Comment
Fixed in Informix Server 14.10.xC5.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
31.08.2020
07.12.2020
07.12.2020
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download