Informix - Problem description

Problem IT03458 Status: Closed

ERROR -768 IN ROUTINE PULL_RANGE POSSIBLE FOR QUERY WITH SEVERAL JOINS WHEN
MULTI_INDEX SCAN IS USED

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
A query with several joins might return error -768 when the 
optimizer chooses a multi-index scan: 
  768: Internal error in routine pull_range: sort pages not 
available.
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* All users                                                    * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Update to IDS-12.10.xC5                                      * 
****************************************************************
Local Fix:
As a workaround, consider disabling multi-index scans using 
undocumented configuration parameter 'MULTI_INDEX_SCAN 0'.
Solution
Problem Fixed In IDS-12.10.xC5
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
29.07.2014
16.10.2015
16.10.2015
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
12.10.xC5 FixList
12.10.xC5.W1 FixList