Problem IT16926 Status: Closed

INSTANCE CRASH IN SQLMON_STMT::ESTIM_STMT_INFO_SZ

product:
DB2 FOR LUW / DB2FORLUW / A50 - DB2
Problem description:
Instance crash with signal 11 in monitoring code.  This is a
sample stack:

sqlmon_stmt::estim_stmt_info_sz
sqlmonszagnt
sqlmonszbackend
sqlesrvr
sqleMappingFnServer
sqlerKnownProcedure
sqlerCallDL
sqljs_ddm_excsqlstt
sqljsParseRdbAccessed
sqljsParse
sqljsDrdaAsDriver
sqeAgent::RunEDU
sqzEDUObj::EDUDriver
sqloEDUEntry
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* ALL                                                          *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* See SYSROUTE APARs to see where this APAR is addressed       *
****************************************************************
Local Fix:
Turn off database monitoring
Solution
Workaround
not known / see Local fix