suche 36x36
Latest versionsfixlist
11.1.0.7 FixList
10.5.0.9 FixList
10.1.0.6 FixList
9.8.0.5 FixList
9.7.0.11 FixList
9.5.0.10 FixList
9.1.0.12 FixList
Have problems? - contact us.
Register for free anmeldung-x26
Contact form kontakt-x26

DB2 - Problem description

Problem IT18771 Status: Closed

PURESCALE: QUERY MIGHT RETURNS WRONG RESULT WHEN INPLACE (ONLINE) TABLE
REORGANIZATION IS RUNNING

product:
DB2 FOR LUW / DB2FORLUW / A50 - DB2
Problem description:
In pureScale environments, a query using an ISCAN-FETCH plan 
with UR or CS isolation level might return too few rows while 
inplace (online) table reorganization is running against the 
table.  The problem only affects DB2 version 10.5 on FixPack 4 
to FixPack 8.
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* ALL                                                          * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to Db2 10.5 Fix Pack 9 or higher                     * 
****************************************************************
Local Fix:
Use the WAIT FOR OUTCOME option or a stronger isolation level on 
the affected SELECT statement.
Solution
First fixed in Db2 10.5 Fix Pack 9
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
11.01.2017
29.09.2017
12.10.2017
Problem solved at the following versions (IBM BugInfos)
9.0.
Problem solved according to the fixlist(s) of the following version(s)