suche 36x36
Latest versionsfixlist
11.1.0.7 FixList
10.5.0.9 FixList
10.1.0.6 FixList
9.8.0.5 FixList
9.7.0.11 FixList
9.5.0.10 FixList
9.1.0.12 FixList
Have problems? - contact us.
Register for free anmeldung-x26
Contact form kontakt-x26

DB2 - Problem description

Problem IT25455 Status: Closed

DB2 MAY TERMINATE ABNORMALLY DURING COMPILATION OF A QUERY WITH OPTIMIZER
GUIDELINE

product:
DB2 FOR LUW / DB2FORLUW / A50 - DB2
Problem description:
Db2 may terminate abnormally during compilation of a query which
contains a malformed optimizer guideline.

Trap file will have the following functions on the top of the
stack:

sqlno_profile_sax_handler::dispatch
xml4c_5_8::SAXParser::startElement
xml4c_5_8::IGXMLScanner::scanStartTag
xml4c_5_8::IGXMLScanner::scanContent
xml4c_5_8::IGXMLScanner::scanDocument
xml4c_5_8::SAXParser::parse
sqlno_profileIO_parse + 0x04a2
sqlno_hint_load_optprofile + 0x012c
sqlno_hint_get_optprofile
sqlnnProcessProfile
sqlnp_main
sqlnn_cmpl
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* All                                                          *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to DB2 version 10.5 Fix Pack 9 or higher.            *
****************************************************************
Local Fix:
Contact Db2 support
Solution
Workaround
not known / see Local fix
BUG-Tracking
forerunner  : 
follow-up : IT25525 
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
22.06.2018
28.06.2018
28.06.2018
Problem solved at the following versions (IBM BugInfos)
9.0.
Problem solved according to the fixlist(s) of the following version(s)