DB2 - Problem description

Problem IT25628 Status: Closed

WIN32 ONLY: DB2LEVEL GIVES SQL1022C IF INSTANCE NAME IS LONGER THAN 7
BYTES.

product:
DB2 FOR LUW / DB2FORLUW / B10 - DB2
Problem description:
Win32 only: db2level gives SQL1022C if instance name is longer
than 7 bytes.
This steps illustrates how this problem happens.

1. Install Data Server Client 32-bit.
2. Create an instance named 8 bytes.
C:>db2icrt DB123456

3. Switch to the instance
C:>set DB2INSTANCE=DB123456

4. Run db2level.
C:>db2level
SQL1022C There is not enough memory available to process the
command.

CLP does not return errors, but some Db2 commands may fail.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* ALL                                                          *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Db2 11.1 Mod 4 Fixpack 5 or higher                *
****************************************************************
Local Fix:
Use instance name shorter than 8 bytes.
Solution
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
10.07.2018
16.01.2020
16.01.2020
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)