DB2 - Problem description

Problem IT38655 Status: Closed

FEDERATED OPERATIONS MIGHT LEAD TO INSTANCE CRASH WHEN HEALTH MONITOR IS
TURNED ON

product:
DB2 FOR LUW / DB2FORLUW / B10 - DB2
Problem description:
Due to the way the monitor data structure is managed, it can
sometimes lead to a Federated operation making an invalid access
to the data structure.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* All Federation users                                         *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to DB2 11.1.4.7                                      *
****************************************************************
Local Fix:
The local work-around is to turn off the health monitor.
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* All Federation users                                         *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to DB2 11.1.4.7                                      *
****************************************************************
Comment
Problem fixed in DB2 11.1.4.7
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
08.10.2021
17.04.2022
17.04.2022
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)