Informix - Problem description
Problem IT09190 | Status: Closed |
SPL PROCEDURES WITH DEFAULT PARAMETERS OF TYPE LIST CAN SEGV ASSERT IN VALSTORE WHEN EXECUTING PREPARED 'EXECUTE PROCEDURE' MULT | |
product: | |
INFORMIX SERVER / 5725A3900 / B70 - IDS 11.70 | |
Problem description: | |
The problem is typified by a stack like: siginfo: 0x0000000101a24620 si_signo: 11 si_code: 1 si_errno: 0 si_pid: 262144 si_uid: 0 si_addr: 0x0004000000000034 si_value: 0x0000000000000000 si_fd: 262144 oninit :: valstore oninit :: setvardata oninit :: udrlm_spl_execute oninit :: udrlm_exec_routine oninit :: udr_execute oninit :: exroutine oninit :: execproc oninit :: aud_execproc oninit :: excommand oninit :: sq_execute oninit :: sqmain oninit :: listen_verify oninit :: spawn_thread oninit :: th_init_initgls oninit :: startup | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * Collection users with default values * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 11.70.xC9 * **************************************************************** | |
Local Fix: | |
Solution | |
Problem Fixed In IBM Informix Server 11.70.xC9 | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 29.05.2015 09.06.2017 09.06.2017 |
Problem solved at the following versions (IBM BugInfos) | |
11.70.xC9 | |
Problem solved according to the fixlist(s) of the following version(s) |