Informix - Problem description
Problem IT10603 | Status: Closed |
HDR PAIR NOT AUTO-RECONNECTING IF PRIMARY RESTARTED WHILE NETWORK DOWN | |
product: | |
INFORMIX SERVER / 5725A3900 / B70 - IDS 11.70 | |
Problem description: | |
If an HDR primary can't reach its secondary at startup (or when just having been made a primary) it won't retry and rather wait on the secondary to become available and initiate the connection. Yet a secondary losing connection to the primary during normal operation wouldn't attempt to reconnect either. This can lead to a situation where, if the primary got restarted during a network outage, the two would never auto-reconnect once the network is available again. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * All users * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 11.70xC9 * **************************************************************** | |
Local Fix: | |
Use 'onmode -d primary ...' (on primary) or 'onmode -d secondary ...' (on secondary) to manually reconnect the two. | |
Solution | |
Problem Fixed In IBM Informix Server 11.70xC9 | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 10.08.2015 09.06.2017 09.06.2017 |
Problem solved at the following versions (IBM BugInfos) | |
11.70.xC9 | |
Problem solved according to the fixlist(s) of the following version(s) |