Informix - Problem description

Problem IT12541 Status: Closed

WITH THE FIX OF IT10301 THE ENGINE CAN FALSELY REPORT ERROR -692WHILE
DELETING FROM A TEMP TABLE WITH UNIQUE OR PK CONSTRAINT

product:
INFORMIX SERVER / 5725A3900 / B70 - IDS 11.70
Problem description:
If you run IBM Informix Server version which contains the fix
for APAR IT10301 and you use temporary tables with
a unique or a primary key constraint defined, the engine may
report the error -692 ( Key value for constraint (on table
) is still being referenced.) when you do a delete from
such a temp table.
The fix of IT10301 changed the way the constrid for constraints
in temp tables are assigned - instead of using the next serial
value from the sysconstraints system catalog a session's
internal counter is now used. For each session this counter
starts from 0. The problem occurs when the constrid generated by
this counter matches a constrid of some PK constraint defined in
the sysconstraints system catalog.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Temporary tables with a unique or a primary key constraint   *
* defined, may receive -692 while using that temp table.       *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Update to IBM Informix Server 11.70.xC9                      *
****************************************************************
Local Fix:
Solution
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
02.12.2015
09.06.2017
09.06.2017
Problem solved at the following versions (IBM BugInfos)
11.70.xC9
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download