Problem IT12813 Status: Closed

SERIAL COLUMN GOES OUT OF SEQUENCE WHEN ALTERED FROM SERIAL TO SERIAL8 AND
SERIAL HAS WRAPPED

product:
INFORMIX SERVER / 5725A3900 / B70 - IDS 11.70
Problem description:
When you insert the value 0 into a serial column, the next
available value will be inserted. When that value reaches the
maximum value 2147483647 the internal variable tracking the
serial value will wrap-around to the maximum negative value and
the advance towards zero. For this range of values a positive
number will still be inserted into the row.

If you alter your table from a SERIAL to SERIAL8 while this
internal reference is in this negative range, the sequence
inserted is wrong.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Using ALTER TABLE to change a SERIAL column to either        *
* SERIAL8 or BIGSERIAL data type after a wrap around of the    *
* serial value happened.                                       *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* Doing an ALTER TABLE to change a SERIAL column to either     *
* SERIAL8 or BIGSERIAL data type after a wrap around of the    *
* serial value happened causes the serial value to restart     *
* from 1 instead of continuing with a value of MAXINT + 1.     *
****************************************************************
* RECOMMENDATION:                                              *
* Update to IBM Informix Server 11.70.xC9 or later version.    *
****************************************************************
Local Fix:
Solution
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
16.12.2015
09.06.2017
09.06.2017
Problem solved at the following versions (IBM BugInfos)
11.70.xC9
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download