Informix - Problem description
Problem IT13536 | Status: Closed |
POSSIBLE ENDLESS LOOP IN CASE OF BROKEN REMOTE CONNECTION | |
product: | |
INFORMIX SERVER / 5725A3900 / B70 - IDS 11.70 | |
Problem description: | |
If a remote (server to server) connection breaks while just transmitting blob type host variables, the sending side will be caught in an endless loop, consuming a CPU VP and never yielding. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * unstable ISTAR environment * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 11.70.xC9 * **************************************************************** | |
Local Fix: | |
Solution | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 01.02.2016 09.06.2017 09.06.2017 |
Problem solved at the following versions (IBM BugInfos) | |
11.70.xC9 | |
Problem solved according to the fixlist(s) of the following version(s) |