Informix - Problem description
Problem IT14480 | Status: Closed |
CONNECTION MANAGER SEGVS WITH A VARIETY OF MEMORY ERRORS WHEN DBSERVERS OF AN HDR CLUSTER USE CSM ENCRYPTION | |
product: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problem description: | |
If DBSERVERS in a HDR Cluster use csm=ENCCSM, Connection Manager will segv with one of the following possible errors: *** Error in `/opt/ibm/informix_csdk/bin/oncmsm': double free or corruption (out): 0x00007f32a754c5c0 *** -OR- *** Error in `/opt/ibm/informix_csdk/bin/oncmsm': munmap_chunk(): invalid pointer: 0x00007f1c0b5f8b40 *** | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * informix Connection Manager with CSM encryption * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC7 * **************************************************************** | |
Local Fix: | |
Solution | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 25.03.2016 28.06.2016 28.06.2016 |
Problem solved at the following versions (IBM BugInfos) | |
12.10.xC7 | |
Problem solved according to the fixlist(s) of the following version(s) |