Informix - Problem description
Problem IT14543 | Status: Closed |
ATTEMPTING TO DROP TIMESERIES TABLE AFTER INTERRUPTING A LOAD PROCESS RETURNS ERROR -214 / ISAM: -110 | |
product: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problem description: | |
When using a raw table with TimeSeries columns, interrupting a load causes corruption and the table cannot be dropped or deleted from. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * informix timeseries users trying to use RAW timeseries base * * tables * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Raw tables are not supported in TimeSeries. The customer * * cannot use them. Upgrade to the next release 12.10.xC8 or * * higher to get the code to prevent the user from * * inadvertently using RAW tables to load data. * **************************************************************** | |
Local Fix: | |
Solution | |
Workaround | |
not known / see Local fix | |
Comment | |
This fix prevents the user from loading Timeseries data stored in a container to a raw timeseries base table. | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 30.03.2016 29.06.2016 29.06.2016 |
Problem solved at the following versions (IBM BugInfos) | |
12.10.xC8 | |
Problem solved according to the fixlist(s) of the following version(s) |