Informix - Problem description
Problem IT15455 | Status: Closed |
AN ONINIT PROCESS CAN HANG WAITING FOR A DEBUGGER IF A PROXYDISPATCH THREAD HIT AN ERROR IN SMX_RECV | |
product: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problem description: | |
After a proxyDispatch thread receives an error from smx_recv, no new connections can be made to the primary server and "oninit pid xxx waiting for debugger" message can be seen in the online log. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * This only applies to the following uncommon situations when * * using updatable secondary servers: * * * * 1. Begin work attempted while already in a transaction. * * 2. An SMX receive fails when trying to read an sblob or dml * * operation from secondary * * 3. SMX error receiving DDL from secondary. * * 4. SMX error receiving DDL Create DB. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC8 * **************************************************************** | |
Local Fix: | |
Used onmode -i to release the oninit. | |
Solution | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 25.05.2016 09.12.2016 09.12.2016 |
Problem solved at the following versions (IBM BugInfos) | |
12.10.xC8 | |
Problem solved according to the fixlist(s) of the following version(s) |