Informix - Problem description
Problem IT16652 | Status: Closed |
LOGICAL LOG FILE HAS LF_WAIT4FLUSH FLAG SET AND CANNOT BE BACKEDUP (AFTER ONCLEAN -KY) | |
product: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problem description: | |
After the engine is abnormally shutdown or "onclean -ky" is run, the logical log could have the LF_WAIT4FLUSH flag (0x100) set. This will cause an ontape/onbar logical log backup to hang and eventually block the whole engine. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * Very rare condition but will cause the engine to hang trying * * to backup the logical logs * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to IDS 12.10.xC8 when available or request a patch. * **************************************************************** | |
Local Fix: | |
Changing LTAPEDEV to /dev/null may release the situation. | |
Solution | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 17.08.2016 09.12.2016 09.12.2016 |
Problem solved at the following versions (IBM BugInfos) | |
12.10.xC8 | |
Problem solved according to the fixlist(s) of the following version(s) |