Informix - Problem description
Problem IT16653 | Status: Closed |
EXECUTING A REMOTE STORED PROCEDURE MAY RESULT IN -674 | |
product: | |
INFORMIX SERVER / 5725A3900 / B50 - IDS 11.50 | |
Problem description: | |
Executing a remote stored procedure within another stored procedure may result in error -674. A "call d2@server2:proc2(var1);" fails with -674 but "call d2@server2:proc2(var1::int);" succeeds. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * informix user with remote procedure * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC8 * **************************************************************** | |
Local Fix: | |
Solution | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 17.08.2016 09.12.2016 09.12.2016 |
Problem solved at the following versions (IBM BugInfos) | |
12.10.xC8 | |
Problem solved according to the fixlist(s) of the following version(s) |