Informix - Problem description
Problem IT17319 | Status: Closed |
REMOTE QUERY HANGS WHEN USING TWO NETWORK CARDS | |
product: | |
IBM IDS ENTRP E / 5724L2304 / B15 - IDS 11.50 | |
Problem description: | |
The problem is seen when a session on machine A performs a remote select to machine B using one server name associated with one network card and then (in the same session) performs another remote select to machine B but using a different server name which is associated with a different network card on the same machine. This is the stack that is seen on machine A ... resume yield_processor_mvp mt_wait net_buf_get recvsocket tlRecv slSQIreqS slSQIreqDone slSQIreq pfConReq cmReqSync cmConReq ascRequest ASF_Call dd_newconnect dd_remconnect remcatalog readtab ddgettable_hierarchy ddgettable aud_ddgettable gettab tlgetddtab spgettab tlp2tnode tbl2tab sel2cb qblk2cb stmt2cb p_sp2cb parsecmd sqcmd sq_cmnd sq_prepare sqmain If INFORMIXCONTIME and INFORMIXCONTRETRY are set to 1, then a 908 error is raised very quickly. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * remote instance with two or more network ip addresses * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 11.50.xC10 * **************************************************************** | |
Local Fix: | |
Solution | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 03.10.2016 15.06.2017 15.06.2017 |
Problem solved at the following versions (IBM BugInfos) | |
11.50.xC10 | |
Problem solved according to the fixlist(s) of the following version(s) |