Informix - Problem description
Problem IT17834 | Status: Closed |
TABLE LEVEL RESTORE POINT IN TIME FAILS FOR UNICODE DB | |
product: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problem description: | |
Archecker gets a GLS error -46 when attempting a Point in Time restore. Â | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * GLS+ARCHIVE * **************************************************************** * PROBLEM DESCRIPTION: * * Point in time table level restore may experience GLS error * * 46 and/or error -909 "Invalid database name format". * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix version 11.70.xC9 or to Informix * * 12.10.xC9. * **************************************************************** | |
Local Fix: | |
Solution | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 07.11.2016 10.07.2017 10.07.2017 |
Problem solved at the following versions (IBM BugInfos) | |
11.70.xC9, 12.10.xC9 | |
Problem solved according to the fixlist(s) of the following version(s) |