Problem IT18894 | Status: Closed |
HDR SECONDARY XCHG THREAD CAN LOOP ENDLESSLY OR SEGV IN IXRFIND | |
product: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problem description: | |
A HDR Secondary thread can loop endlessly when running a stress test that executes two transactions by many threads. The first transaction creates a raw table, various indexes on this table and loads a small amount of data. The second transaction drops the table. This will ultimately lead to a "DR: ping timeout" on the primary and then on the HDR secondary you will soon see messages like: 09:44:02 DR: Received connection request from remote server when DR is not Off [Local type: Secondary, Current state: ?] [Remote type: Primary] 09:44:06 DR: ping timeout 09:44:15 DR: Received connection request from remote server when DR is not Off [Local type: Secondary, Current state: FAILED] [Remote type: Primary] Usually one of three things occurs: 1. Most frequently, you can check to see that there will be an xchg_ thread running continually on a cpu vp. It's spinning endlessly in ixrfind(). $ rasu pstack 632 #0 ixrfind () #1 rspnlockid () #2 plogredo () #3 rlogm_redo () #4 next_recvr () #5 prod_loop2 () #6 producer_thread () #7 startup () #8 ?? () 2. Sometimes, after the "DR: ping timeout" on the HDR secondary, an xchg thread will segv in ixrfind() and assert 10:10:35 Stack for thread: 41 xchg_1.1 (../bin/oninit) afstack (../bin/oninit) mt_ex_throw_sig (../bin/oninit) afsig_handler (Linux) (../bin/oninit) ixrfind (../bin/oninit) rspnlockid (../bin/oninit) plogredo (../bin/oninit) rlogm_redo (../bin/oninit) next_recvr (../bin/oninit) producer_thread (../bin/oninit) startup 3. Less often, whatever causes the the bad list in ixrfind() 'corrects' itself and the thread comes out of its loop and continues on. I say 'corrects' loosely because it's just a second dose of corruption that causes the list to terminate rather than endlessly loop. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * HDR users rapidly reading / dropping indexes * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC9 * **************************************************************** | |
Local Fix: | |
Solution | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 18.01.2017 10.07.2017 10.07.2017 |
Problem solved at the following versions (IBM BugInfos) | |
12.10.xC9 | |
Problem solved according to the fixlist(s) of the following version(s) |