Problem IT19415 Status: Closed

"ERROR COMPRESSION OPERATION ALREADY IN PROGRESS ..." WHEN PARALLEL
INSERTS SIMULTANEOUSLY CROSS COMPRESSION THRESHOLD

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
Simultaneous inserts into a new 'compressed' table (or fragment
of a table) could also simultaneously trigger auto-compression
when crossing the minimum number of rows for compression.  While
not causing any real harm, this would produce potentially
confusing messages like these:

  Auto compressing partition  in table
::
  Auto compressing partition  in table
::
  ERROR Compression operation already in progress for partition
 in table ::
  Auto compressing partition  in table
::
  ERROR Compression operation already in progress for partition
 in table ::
  Compression dictionary created for partition  table
:: by auto compression.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* using auto-compression and parallel inserts                  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* Parallel inserts into a new table or fragment defined as     *
* auto-compressing can trigger "ERROR Compression operation    *
* already in progress" errors.                                 *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix version 12.10.xC9.                       *
****************************************************************
Local Fix:
Solution
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
24.02.2017
10.07.2017
10.07.2017
Problem solved at the following versions (IBM BugInfos)
12.10.xC9
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download