Informix - Problem description
Problem IT21280 | Status: Closed |
WITH DELAY_APPLY SET WHEN PRIMARY IS RESTARTED AFTER THE LOGICALLOG WRAP IT STOPS SENDING NEW LOGICAL LOGS TO RSS UNTIL DELAY_A | |
product: | |
INFORMIX SERVER / 5725A3900 / B70 - IDS 11.70 | |
Problem description: | |
When DELAY_APPLY is set on RSS and primary is restarted after the logical log wrap, RSS doesn't reconnect to Primary and new logical logs are not sent to the staging directory until DELAY_APPLY is elapsed and logical logs from staging directory are applied at RSS. Following message is seen in the RSS online.log 14:45:31 SMX thread is exiting 14:45:34 RSS: Lost connection to pri_root 14:45:52 RSS: Reconnected to pri_root 14:45:52 RSS: Start failure recovery from tape ... This behavior is NOT seen on 12.10.FC8. | |
Problem Summary: | |
Local Fix: | |
Solution | |
Workaround | |
not known / see Local fix | |
Comment | |
This APAR is a duplicate of IT27580 | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 03.07.2017 25.09.2019 26.10.2019 |
Problem solved at the following versions (IBM BugInfos) | |
Problem solved according to the fixlist(s) of the following version(s) |