Informix - Problem description

Problem IT22080 Status: Closed

NON-ROOT IN-PLACE UPGRADE FROM 12.10.FC1 TO 12.10.FC9 FAILS WITHSCHAPI:
SQL ERROR -302

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
Non root in-place upgrade from 12.10.FC1 to 12.10.FC9 assert
fails...

15:16:11  SCHAPI: SQL Error -302, ISAM Error 0 in file
/opt/informix/1210FC1/etc/sysadmin/conv/upgrade_1210xC8.sql at
line 89
15:16:11  Conv/rev: Failed to convert component SCHAPI to
component version 8
15:16:11  Conv/rev: Failed to convert for component SCHAPI
15:16:11  Conversion failed.
15:16:11  *** Conversion failed ***
        CONVERSION_GUARD was on. To go back to the original
version
        of IDS, run onrestorept.
15:16:11  Assert Failed: *** Conversion failed ***
        CONVERSION_GUARD was on. To go back to the original
version
        of IDS, run onrestorept.
15:16:11  IBM Informix Dynamic Server Version 12.10.FC9
15:16:11   Who: Session(7, informix@server, 0, 0x44c31f18)
                Thread(24, convert, 44bedfc0, 1)
                File: framework.c Line: 962
15:16:11   Results: Dynamic Server must abort
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users doing upgrade to 12.10.xc9 from a previous version of  *
* 12.10 before 12.10.xC8                                       *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to 12.10.xC9W1                                       *
****************************************************************
Local Fix:
Solution
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
21.08.2017
01.11.2017
01.11.2017
Problem solved at the following versions (IBM BugInfos)
12.10.xC9
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download