Problem IT27471 | Status: Closed |
FAILED CONNECTIONS COULD LEAD TO INCORRECT VALUE FOR SHMEM->SH_RSNACTIVE WHICH COULD CAUSE PHYSICAL LOG OVERFLOW ASSERTIONS | |
product: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problem description: | |
Under specific failed connections, it's possible that shmem->sh_rsnactive will be decremented prior to it having been incremented. If this happens often enough shmem->sh_rsnactive can go to a negative value. This can lead to physical log overflow because this value is used in the code to determine if a non-blocking checkpoint needs to be switched to a blocking checkpoint, to prevent the physical log from filling. The most likely cause of failed connections would be servers that have SHMTOTAL set to a non-zero value, and the server has allocated SHMTOTAL amount of memory. | |
Problem Summary: | |
Local Fix: | |
Solution | |
Workaround | |
not known / see Local fix | |
Comment | |
This APAR is a duplicate of IT28628 | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 21.12.2018 04.12.2019 04.12.2019 |
Problem solved at the following versions (IBM BugInfos) | |