Informix - Problem description

Problem IT27517 Status: Closed

SQL TRACING DOES NOT COLLECT RUNTIME INFORMATION WHEN STORED PROCEDURE IS
EXECUTED FOR THE FIRST TIME

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
After switching on sql tracing, Run Time isn't collected when
stored procedure is executed the first time.

onstat -g his shows

 Statement information:
  Sess_id  User_id  Stmt Type        Finish Time    Run Time
TX Stamp   PDQ
  30       28410    EXEC PROCEDURE   13:09:16       0.0000
cd90e      0

the first time but

 Statement information:
  Sess_id  User_id  Stmt Type        Finish Time    Run Time
TX Stamp   PDQ
  30       28410    EXEC PROCEDURE   13:09:16       0.0075
cda84      0

the second time.

When there is nothing in the SP all is fine.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of IDS 12.10.xC10 and older versions.                  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* SQL tracing does not collect Run Time information when       *
* stored procedure is executed for the first time.             *
****************************************************************
* RECOMMENDATION:                                              *
****************************************************************
Local Fix:
Solution
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
24.12.2018
08.10.2019
08.10.2019
Problem solved at the following versions (IBM BugInfos)
12.10.xC11
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download