DB2 - Problem description
| Problem IC66391 | Status: Closed |
DB2IUPDT MAY RETURN DBI1177W IF A SPECIAL BUILD WAS INSTALLED INA SEPERATE INSTALLATION PATH | |
| product: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
| Problem description: | |
If you install a DB2 Special Build (db2setup/db2_install) in a
different directory than the previous installation then
db2iupdt may fail with a misleading DBI1177W message:
DBI1177W Updating an instance to a code level that is lower than
the current level used by the instance.
This problem is caused by a invalid comparison of the build
level strings in the instance update scripts (i.e.: sYYMMDD vs.
special_NNNNN).
Note: If you are going to install a Special Build provided by
DB2 Technical Support then the warning can be ignored and
db2iupdt should be run with the "-D" option to overcome the
problem. | |
| Problem Summary: | |
Users Affected: ALL Problem Description: See Error Description. Problem Summary: See Error Description. | |
| Local Fix: | |
Run "db2iupdt -D" as suggested by the db2iupdt script to skip the build level check. or Alternativly use the "installFixPack" script to install the Special Build in the same path than the previous installation. In this case the problem does not occur. | |
| Solution | |
First fixed in DB2 UDB Version 9.7, FixPak 1 (build s091114) | |
| Workaround | |
see Local Fix. | |
| Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 18.02.2010 06.04.2010 06.04.2010 |
| Problem solved at the following versions (IBM BugInfos) | |
9.7. | |
| Problem solved according to the fixlist(s) of the following version(s) | |