Informix - Problem description
| Problem IT05878 | Status: Closed |
COLUMN NAME IN TSCONTAINERTABLE EXCEEDING 18 BYTES COULD BLOCK MIGRATION | |
| product: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
| Problem description: | |
A value in column name in tscontainertable which exceeds 18
bytes could block the migration.
Message in the online.log:
08:46:57 Conv/rev: blade conversion failed. See
$INFORMIXDIR/etc/conv/convblade1210xC4.out
convblade1210xC4.out:
EXECUTE FUNCTION SYSBldPrepare('any','migrate');
(U0001) - registerBlade - Unable to register TimeSeries.6.00.FC4
- unknown error - check online log and sysblderrorlog table for
more information | |
| Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * TimeSeries * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IDS-12.10.xC5 * **************************************************************** | |
| Local Fix: | |
| Solution | |
Problem Fixed In IDS-12.10.xC5 | |
| Workaround | |
not known / see Local fix | |
| Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 02.12.2014 16.10.2015 16.10.2015 |
| Problem solved at the following versions (IBM BugInfos) | |
| Problem solved according to the fixlist(s) of the following version(s) | |
| 12.10.xC5 |
|
| 12.10.xC5.W1 |
|