DB2 - Problembeschreibung
| Problem IC67131 | Status: Geschlossen |
DEADLOCK MONITOR ELEMENT MAY NOT GET UPDATED IN APPLICATION SNAPSHOT. | |
| Produkt: | |
DB2 FOR LUW / DB2FORLUW / 980 - DB2 | |
| Problembeschreibung: | |
deadlock monitor element in application snapshot may not get updated when deadlock happen. From the application snapshot output, the "Internal rollbacks due to deadlock" element is more that 1 but the "Deadlocks detected" element is still 0. Lock timeout (seconds) = -1 Locks held by application = 0 Lock waits since connect = 1 Time application waited on locks (ms) = 7272 Deadlocks detected = 0 Lock escalations = 0 Exclusive lock escalations = 0 Number of Lock Timeouts since connected = 0 .... Internal automatic rebinds = 0 Internal rows deleted = 0 Internal rows inserted = 0 Internal rows updated = 0 Internal commits = 1 Internal rollbacks = 1 Internal rollbacks due to deadlock = 1 | |
| Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * All platform * **************************************************************** * PROBLEM DESCRIPTION: * * see APAR description * **************************************************************** * RECOMMENDATION: * * Upgrade to V9.8 FP3 * **************************************************************** | |
| Local-Fix: | |
| verfügbare FixPacks: | |
DB2 Version 9.8 Fix Pack 3 for Linux, UNIX, and Windows | |
| Lösung | |
Fix in V9.8 FP3. | |
| Workaround | |
keiner bekannt / siehe Local-Fix | |
| Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 11.03.2010 20.12.2010 20.12.2010 |
| Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.8.FP3 | |
| Problem behoben lt. FixList in der Version | |
| 9.8.0.3 |
|