DB2 - Problem description

Problem IC66796 Status: Closed

CONTROL CENTER UNRESPONSIVE WHEN UPDATING text based DBM CFG parameter

product:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problem description:
The Control Center in DB2 v9.7 has a problem updating DBM CFG 
parameters. Specifically the ones that take a text string, like 
SVCENAME. You can update SVCENAME to a number, but not to a 
name. After updating SVCENAME, and pressing 'OK', nothing 
happens. The 'Change DBM Configuration Parameter' window remains 
until you click 'Cancel'.
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* All users of the Control Center                              * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* The Control Center is unable to update DBM CFG               * 
* parametersthat take a text string, like SVCENAME. It does    * 
* not have aproblem updating numerical values, and you can     * 
* updateSVCENAME with a number. If you attempt to update       * 
* SVCENAME toa text string, after clicking on 'OK' nothing     * 
* will happen.The 'Change DBM Configuration Parameter' window  * 
* will remainuntil you click 'Cancel'.                         * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Workaround is to use the 'update dbm cfg' command.           * 
****************************************************************
Local Fix:
None. Work-around is to manually update the dbm cfg from the CLP
available fix packs:
DB2 Version 9.7 Fix Pack 2 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 4 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 5 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Solution
First Fixed in DB2 v9.7 FP2
Workaround
not known / see Local fix
BUG-Tracking
forerunner  : APAR is sysrouted TO one or more of the following: IC66873 
follow-up : 
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
02.03.2010
22.06.2010
22.06.2010
Problem solved at the following versions (IBM BugInfos)
9.7.FP2
Problem solved according to the fixlist(s) of the following version(s)
9.7.0.2 FixList