Latest versionsfixlist
11.1.0.7 FixList
10.5.0.9 FixList
10.1.0.6 FixList
9.8.0.5 FixList
9.7.0.11 FixList
9.5.0.10 FixList
9.1.0.12 FixList
Have problems? - contact us.
Register for free anmeldung-x26
Contact form kontakt-x26

DB2 - Problem description

Problem IC75306 Status: Closed

DB2PD OPTIONS -VMSTAT AND -IOSTAT NOT WORKING ON NATIONALIZED LOCALES.

product:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problem description:
db2pd options -vmstat and -iostat not working on nationalized 
locales.it failed with following error. 
 
C:\WINDOWS\system32>db2pd -vmstat 
NT/db2pd_vmstat.C(105): PdhAddCounter failed - rc=-1073738823 
 
 
C:\WINDOWS\system32>db2pd -iostat 
Error determining buffer size 
 
The rc=-1073738823 could be mapped to 0xC0000BB9 - 
PDH_CSTATUS_NO_COUNTER 
The specified counter could not be found
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* All users prior to DB2 V97 FP5                               * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* DB2PD OPTIONS -VMSTAT AND -IOSTAT NOT WORKING ON             * 
* NATIONALIZED LOCALES                                         * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to DB2 V97 FP5 or above                              * 
****************************************************************
Local Fix:
Solution
First fixed in DB2 V97 FP5
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
28.03.2011
18.12.2011
18.12.2011
Problem solved at the following versions (IBM BugInfos)
9.7.FP5
Problem solved according to the fixlist(s) of the following version(s)