Latest versionsfixlist
11.1.0.7 FixList
10.5.0.9 FixList
10.1.0.6 FixList
9.8.0.5 FixList
9.7.0.11 FixList
9.5.0.10 FixList
9.1.0.12 FixList
Have problems? - contact us.
Register for free anmeldung-x26
Contact form kontakt-x26

DB2 - Problem description

Problem IC80515 Status: Closed

MONITOR STMT FIELD ARE BIENG UNINTENTIONALLY RESET TO ZERO IN A PARTICULAR
CASE.

product:
DB2 FOR LUW / DB2FORLUW / 950 - DB2
Problem description:
When an application is bieng monitored , stmt fields  of an 
application are bieng reset to zero when you open a 
new cursor. 
 
This can happen when 
you open cursor1 for a table , then do some fetches 
then if you later open another cursor2  the stmt field 
such as rows_read , rows_written will be reset to zero 
for cursor1.
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* All platform                                                 * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See APAR Description.                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* upgrade to v9.5 fp9.                                         * 
****************************************************************
Local Fix:
available fix packs:
DB2 Version 9.5 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.5 Fix Pack 10 for Linux, UNIX, and Windows

Solution
v9.5 fp9 will contain fix
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
20.12.2011
07.03.2012
07.03.2012
Problem solved at the following versions (IBM BugInfos)
9.5.FP9
Problem solved according to the fixlist(s) of the following version(s)
9.5.0.9 FixList