DB2 - Problem description

Problem IC97597 Status: Closed

CLI APPLICATION MAY CRASH IN CLI_EXECCMRIFLUSHARRAY() FUNCTION

product:
DB2 CONNECT / DB2CONNCT / 970 - DB2
Problem description:
If your CLI application has the multi-row insert (MRI) feature 
enabled, your application may 
crash in the function CLIexecCMRIFlushArray(). 
 
This feature enables CLI applications that are connected to the 
DB2 for z/OS servers to convert array input chaining into 
column-wise array input for INSERT operations.
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* DB2 CLI with MRI feature enabled                             * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to DB2 9.7 FP10 or later                             * 
****************************************************************
Local Fix:
Disable the MRI feature
Solution
The problem was first fixed in DB2 9.7 FP10
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
12.11.2013
01.12.2014
01.12.2014
Problem solved at the following versions (IBM BugInfos)
9.7.FP10
Problem solved according to the fixlist(s) of the following version(s)