Problem IC61770 Status: Geschlossen

THE CONFIGURATION ASSISTANT FOR BOTH V8 AND V9 (WHEN BOTH ARE INSTALLED)
USES THE SAME REGISTRY KEY TO LOCATE IBMDADB2.DLL

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
When both DB2 v8 and DB2 v9 are installed, the v9 Configuration 
Assistant uses the v8 Registry Key for ibmdadb2.dll. This means 
that both the OLE DB and the ADO Connection Tests fail. 
 
The v9 Configuration Assistant reads 
 HKEY_CLASSES_ROOT\IBMDADB2\CLSID 
which is the v8 key. It should be reading 
 HKEY_CLASSES_ROOT\IBMDADB2.DB2COPY1 
instead. (DB2COPY1 being the v9 installation) 
 
Please note that this problem does not affect OLEDB 
applications, and this is specific to Windows
Problem-Zusammenfassung:
Users Affected: All users of the Configuration Assistant on 
Windows with both DB2 v8 and DB2 v9.7 installed. 
 
Problem Description: Testing OLE DB and ADO connectivity from 
the DB2 v9.7 Configuration Assistant will fail. ADO and OLE DB 
applications will work, however. 
 
Recommendation: Do not use the Configuration Assistant to test 
ADO and OLE DB connectivity.
Local-Fix:
Local Fix: None 
Work Around: None
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 1 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 2 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 4 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 5 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
First fixed in FP1, defect wsdbu00551700
Workaround
keiner bekannt / siehe Local-Fix
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
28.06.2009
22.12.2009
22.12.2009
Problem behoben ab folgender Versionen (IBM BugInfos)
Problem behoben lt. FixList in der Version
9.7.0.1 FixList