DB2 - Problembeschreibung

Problem IC61965 Status: Geschlossen

OLEDB DRIVER RETURNS CLI0100E ON WINDOWS 64-BIT PLATFORM

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
An OLE DB application using the IBMDADB2 provider on a Windows 
64-bit platform may receive a CLI0100E - "Wrong Number of 
Parameters" errors if executing a statement with parameter 
markers. 
. 
This problem will happen despite the fact that the application 
properly bound a parameter marker to the statement.
Problem-Zusammenfassung:
Users Affected:  DB2 OLE DB users running on Windows 64-bit 
Problem Description:  OLE DB applications receiving CLI0100E 
 errors on Windows 64-bit platforms.
Local-Fix:
Use either an ODBC datasource, or either the ODBC.NET or DB2.NET 
data provider if running a .NET application.   This problem 
will not happen in a 32-bit environment. 
. 
The db2cli.ini keyword DEFERREDPREPARE=0 will also workaround 
the problem, but may cause a slight performance degradation.
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 1 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 2 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 4 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 5 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
First fixed in DB2 UDB Version 9.7, Fixpak 1
Workaround
see LOCAL FIX
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
09.07.2009
22.12.2009
22.12.2009
Problem behoben ab folgender Versionen (IBM BugInfos)
9.7.
Problem behoben lt. FixList in der Version
9.7.0.1 FixList