DB2 - Problembeschreibung

Problem IC61980 Status: Geschlossen

TESCONN20.EXE, SHIPPED WITH THE DATASERVERCLIENET RETURNS AN ERROR
MESSAGE FOR THE FACTORY LOOKUP

Produkt:
DB2 CONNECT / DB2CONNCT / 970 - DB2
Problembeschreibung:
tesconn20.exe, shipped with the Data Server Driver returns an 
error message for the factory lookup 
in case there was a previous version of Data Server Driver on 
the same system: 
Step 1: Printing version info 
        .NET Framework version: 2.0.50727.3074 
        IDS .NET provider version: 9.0.0.2 
        IDS .NET file version: 9.7.0.2 
        Capability bits: ALLDEFINED 
        Build: 20090522 
        ERROR - Factory lookup failed - exception 
           System.Configuration.ConfigurationErrorsException: 
Der registrierte .Net Framework-Datenp 
rovider kann nicht gefunden bzw. geladen werden. 
   bei System.Data.Common.DbProviderFactories.GetFactory(DataRow 
providerRow) 
   bei System.Data.Common.DbProviderFactories.GetFactory(String 
providerInvariantName) 
   bei TestConn.myClassName.LoadIDS() 
        Warning, failed load of DbFactory for:IBM.Data.Informix 
VSAI is not installed properly 
        Elapsed: 12,8946825 
 
On a new, freshly installed system the lookup works fine: 
Step 1: Printing version info 
        .NET Framework version: 2.0.50727.312 
        IDS .NET provider version: 9.0.0.2 
        IDS .NET file version: 9.7.0.2 
        Capability bits: ALLDEFINED 
        Build: 20090522 
        Factory for invariant name IBM.Data.Informix verified 
VSAI is not installed properly 
        Elapsed: 0,484375
Problem-Zusammenfassung:
TESCONN20.EXE, SHIPPED WITH THE DATASERVERCLIENET RETURNS AN 
ERROR MESSAGE FOR THE FACTORY LOOKUP
Local-Fix:
The following workaround can be used: 
db2nmpcfg -register -level 9.7.0 -migrateIDS 
Program completed successfully 
 
After manually registered, the factory lookup works again: 
Step 1: Printing version info 
 .NET Framework version: 2.0.50727.3074 
 IDS .NET provider version: 9.0.0.2 
 IDS .NET file version: 9.7.0.2 
 Capability bits: ALLDEFINED 
 Build: 20090522 
 Factory for invariant name IBM.Data.Informix verified 
VSAI is not installed properly 
 Elapsed: 0,894474
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 1 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 2 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 4 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 5 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
First Fixed in DB2 Version 9.7 fix pack 1
Workaround
keiner bekannt / siehe Local-Fix
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
10.07.2009
19.03.2010
19.03.2010
Problem behoben ab folgender Versionen (IBM BugInfos)
9.7.FP1
Problem behoben lt. FixList in der Version
9.7.0.1 FixList