| Problem IC63092 | Status: Geschlossen |
ERROR SQL30082N RETURNED FOR SYSPROC.AUTH_GET_INSTANCE_AUTHID | |
| Produkt: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
| Problembeschreibung: | |
The error SQL30082N is returned from the function
SYSPROC.AUTH_GET_INSTANCE_AUTHID
db2 "VALUES SYSPROC.AUTH_GET_INSTANCE_AUTHID()"
1
----------------------------------------------------------------
----------------------------------------------------------------
SQL30082N Security processing failed with reason "24"
("USERNAME AND/OR
PASSWORD INVALID"). SQLSTATE=08001 | |
| Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * Customers will receive the error on the following platforms * * Windows 64bit * * AIX 64bit * * HPUX 64bit * * Solaris 64bit * * Linux PPC 64bit * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description. * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 Version 9.7 Fix Pack 1 * **************************************************************** | |
| Local-Fix: | |
| verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 1 for Linux, UNIX, and Windows | |
| Lösung | |
After applying DB2 Version 9.7 Fix Pack 1, SYSPROC.AUTH_GET_INSTANCE_AUTHID will return the authid of the instance owner. | |
| Workaround | |
keiner bekannt / siehe Local-Fix | |
| Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 09.09.2009 20.01.2010 20.01.2010 |
| Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7.FP1, 9.7.FP1 | |
| Problem behoben lt. FixList in der Version | |
| 9.7.0.1 |
|