DB2 - Problembeschreibung
Problem IC64032 | Status: Geschlossen |
INVALID CHARACTER DATA COULD BE RETURNED IN MONITOR ELEMENTS | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problembeschreibung: | |
Invalid character data could be returned in monitor elements that are not collected when a snapshot for applications is performed. When a snapshot for applications is requested, an internal memory structure is allocated to hold the monitor elements from which the snapshot will be created. This structure is not being fully initialized to zero which means that if a monitor element is not collected then the corresponding member of the structure may contain invalid character data. | |
Problem-Zusammenfassung: | |
See ERROR DESCRIPTION. | |
Local-Fix: | |
verfügbare FixPacks: | |
DB2 Version 9.7 Fix Pack 1 for Linux, UNIX, and Windows | |
Lösung | |
Problem was first fixed in version 9.7 FixPak 1 (s091114). At minimum the fix should be applied to the server. | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 22.10.2009 21.12.2009 21.12.2009 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
9.7. | |
Problem behoben lt. FixList in der Version | |
9.7.0.1 |