DB2 - Problembeschreibung

Problem IC64058 Status: Geschlossen

UNDER CERTAIN CONDITIONS, OPTIMIZER MAY PICK LESS THAN OPTIMAL ACCESS PLAN
DUE TO OVER-ESTIMATED CARDINALITY

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
when only one derived table is referenced in its own query 
block, within the query block if there is a distinct requirement 
and one or more predicates applied to filter the stream, the 
combination may lead to overestimated cardinality and may result 
in a less than optimal access plan.
Problem-Zusammenfassung:
UNDER CERTAIN CONDITIONS, OPTIMIZER MAY PICK LESS THAN OPTIMAL 
ACCESS PLAN DUE TO OVER-ESTIMATED CARDINALITY
Local-Fix:
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 1 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 2 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 4 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 5 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
Problem was first fixed in Version 9.7 Fixpak 1