DB2 - Problembeschreibung

Problem IC64341 Status: Geschlossen

INSERTION WITH ROW-WISE ARRAY INPUT HANGS WHEN A STORED PROCEDURE
IS CALLED BY AN INSERT TRIGGER

Produkt:
DB2 FOR LUW / DB2FORLUW / 970 - DB2
Problembeschreibung:
If you have in your application an insertion with a row-wise 
array input on a table that has an insert trigger calling a 
stored procedure, your application will indefinitly wait. 
The command "db2 list application show detail" will indicate the 
status for your application as "Compiling" or "UOW waiting" 
depending on the version of your DB2 server.
Problem-Zusammenfassung:
**************************************************************** 
* USERS AFFECTED:                                              * 
* ALL                                                          * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* If you have in your application an insertion                 * 
* witharow-wisearray input on a table that has an              * 
* inserttriggercalling astored procedure, your application     * 
* willindefinitlywait.The command "db2 list application        * 
* showdetail" willindicatethe status for your application      * 
* as"Compiling" or"UOWwaiting" depending on the version of     * 
* yourDB2 server.                                              * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to DB2 9.7 FP2 or later.                             * 
****************************************************************
Local-Fix:
verfügbare FixPacks:
DB2 Version 9.7 Fix Pack 2 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 3a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 4 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 5 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 6 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 7 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9a for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 8 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 9 for Linux, UNIX, and Windows
DB2 Version 9.7 Fix Pack 10 for Linux, UNIX, and Windows

Lösung
Upgrade to DB2 9.7 FP2 or later
Workaround
keiner bekannt / siehe Local-Fix